Brand Name:GFUVE
Model Number:LZCK350-10
Certification:CE, UL, ISO9001
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability:50000 PCS/MONTH
Delivery Time:3-7 days
Company Data
Verified Supplier
Contact Person Andy
Business Type: 86-10-85782698
Business Type: Manufacturer
Officials: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Quality: Quality Certifitation Available
Product Details Company Profile
Product Details

100 / 5A Split Core Current Transformer Dry Type


Introduction


The most common usage of current transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. The primary winding of the transformer is connected to the high voltage or high current circuit, and the meter or relay is connected to the secondary circuit. Installation With electricity, suite for power monitor, energy loss etc.

Split core current transformers may also be used as an isolation instrument transformer so that secondary quantities may be used in phase shifting without affecting other primary connected devices.


Applications


LZCK322-10 split core current transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes.The transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.



Features


The semicircular ring core and secondary windings are vacuum poured by high quality epoxide resin in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance.Small size, light weight, small footprint, fixed in the ring network switchgear cable.The cable can cross the current transformer through its internal poles quickly and uniformly.
The Cast Resin Straight-Through Current Transformer can be divided several kinds according to the various current ratio, accuracy and rated loads. The specific parameters are showed in the corresponding to each model parameter tables.



PARAMETERS


Technical parameters 
StandardsIEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13
Accuracy Class0.5S, 0.5%, 1%, 3%
Range of primary rated current100-1500A
Range of Rated load≤10VA
Rated frequency50/60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current150%I1n
Secondary winding power frequency withstand voltage3kV, 1min
Safety Factor Rating(FS) <10
Output signal1A, 5A, 333mV, 1V or 5V(customized)
Cable length2.5m, 5m, 10m(customized)
Flame retardant ABS plastic shell inside, jaw waterproof apron.
Mechanical parameters 
Aperture (mm)Φ55
Dimensions (W×D×H) (mm)180×138×52
Weight (kg)2
Working conditions 
Operating temperature-35°C to +65°C, not exceeding +40°C
Storage temperature-40°C to +70°C
Ingress ProtectionIP65
Environmentoutdoors or indoors
The Height of above sea level0- 3000m
ConditionsNo existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed.

SELECTION GUIDE


Technical parameters 
StandardsIEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Rated primary current30-600A
Rated load≤10VA
Rated frequency50Hz or 60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current120%I1n
Secondary winding power-frequency voltage3kV, 1min
Instrument security factorFS≤10
Mechanical parameters 
Dimensions (W×D×H) (mm)φ50xφ110x52
Weight (kg)1.6
Operating conditions 
Operating temperature-35°C to +55°C
Daily average temp<+40°C
Altitude<3500 meters
ConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

TECHNICAL DATA


TypeLZCK322-10LZCK322-10
PurposeMeasuring current transformerProtection current transformer
RatioAccuracy class and rated load(VA)Accuracy class and rated load(VA)
I1/I20.51310P1510P1010P5
30/1 11.5   
50/1 12  1.25
75/1 1.52.5 12
100/122.53 1.52.5
200/12.5  1.252.5 
300/13.75  1.252.5 
400/17.5  1.252.5 
500/110  1.253 
600/110  1.53 
50/5  2.5   
75/5  2.5   
100/52.5     
200/53.75     
300/55     
400/57.5   2.5 
500/57.5   2.5 
600/510   3.75 

SELECTION GUIDE


ModelPrimary rated currentRated loadAperture (mm)Description (mm)Weight (kg)MaterialWater-proof
LZCK-55100-1500A≤10VAφ55180×138×522PCIP65
LMCK185-10300-3000A≤25VAφ185350×283×554.5PCIP65
LZCK310-10300-600A≤10VAφ50φ50 x φ110 x 321Resinsilicon case (option)
LZCK322-1030-600A≤10VAφ50φ50 x φ110 x 521.6Resinsilicon case (option)
LZCK350-1020-600A≤25VAφ50φ50 x φ110 x 1053.1Resinsilicon case (option)
LZCG530-1030-600A≤20VAφ45φ45 x φ120 x 652.1Resinsilicon case (option)

Wiring diagrams


P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal.
P2, S2 is homonymous terminals (subtractive polarity).


ORDERING INFORMATION

Be sure to the type, current ratio, accuracy class, rated load and use of the products when you plan to make a order. Special specifications could be customized.All kinds of different specifications and parameters current transformers can be made according to your needs.


Product Photo

100 / 5A Core Balance Current Transformer Dry Type 50mm Aperture 0.5% High Accuracy

Company Profile

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core ct and current clamp models etc.

GFUVE is a leader manufacturer of split core current transformer products in China. It is professional in current transformer, potential transformer and related accessory. The product of outdoor split core current transformer develops very quickly in the global market. Our company has achieved certification to ISO9001. The products are sold to over 30 provinces in China and exported to overseas including South America, Middle East, Southeast Asia, Australia and Africa.

Please contact us now for further business relationship. We are here to provide you the best service and the best product.

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China 4mm Banana Connector 1000A/5A Split Core Current Transformer With 110mm & 50m Diameter wholesale

4mm Banana Connector 1000A/5A Split Core Current Transformer With 110mm & 50m Diameter

China IP68 200/5A High Magnetic Core Clamp Ct Transformer / Split Core CT For Electric Meter wholesale

IP68 200/5A High Magnetic Core Clamp Ct Transformer / Split Core CT For Electric Meter

China ABS Cover Split Core Current Transformer CT 2.5VA Burden 0.5% High Accuracy wholesale

ABS Cover Split Core Current Transformer CT 2.5VA Burden 0.5% High Accuracy

China FU16 333mv Mini Dual Core Current Transformer Low Phase Shift For Power Measurement wholesale

FU16 333mv Mini Dual Core Current Transformer Low Phase Shift For Power Measurement

China 200A Outdoor Split Type Current Transformer For Cable Fault Monitoring , Class 0.5 wholesale

200A Outdoor Split Type Current Transformer For Cable Fault Monitoring , Class 0.5

China Resin Cast Split Core Current Transformer 600/5A Network Switchgears Application wholesale

Resin Cast Split Core Current Transformer 600/5A Network Switchgears Application

China GFUVE 100A / 5A Split Core  Clamp On Current Transformer IP67 Outdoor Installation wholesale

GFUVE 100A / 5A Split Core Clamp On Current Transformer IP67 Outdoor Installation

China 50Hz / 60Hz Split Core Current Transformer Epoxy Resin Cast CT 3.1 Kgs Weight wholesale

50Hz / 60Hz Split Core Current Transformer Epoxy Resin Cast CT 3.1 Kgs Weight

China 400kv Class 1 Ring Core Current Transformer Mini Current Transformer Compact Structure wholesale

400kv Class 1 Ring Core Current Transformer Mini Current Transformer Compact Structure

China Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage wholesale

Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage

China Class 1 40kA 5A Waterproof IP67 Split Core Current Transformer wholesale

Class 1 40kA 5A Waterproof IP67 Split Core Current Transformer

Inquiry Cart 0