GF101 Program-controlled Single-phase Standard Power Source, with high stability and excellent working performance, current output as high as 120A, voltage range as wide as 500V.
(Accuracy class: 0.05% or 0.1%)
Application
It is suitable for power department, measuring department, quality control department, research units, institution of higher learning, electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and phantom load.
Features
Electrical parameters | |
Accuracy class | 0.05%, 0.1% |
Power supply | Single phase AC 85-265V, 50/60 Hz |
AC Voltage output | |
Range | 57.7V / 100 V / 220V / 380V, Switch automatically (max 500V) |
Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
Accuracy | 0.05% RG |
Stability | Better than 0.01% RG / 1 min |
Distortion degree | Better than 0.1% (not capacitive load) |
Load capacity | 40VA |
Full load regulation rate | Less than 0.01% RG |
Full load regulation time | Less than 1ms |
Temperature drift | 8 PPM / °C |
Long-term stability | 60 PPM/year |
AC Current output | |
Range | 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, Switch automatically |
Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
Accuracy | 0.05% RG |
Stability | Better than 0.01% RG/1 min |
Distortion degree | Better than 0.1% (not capacitive load) |
Load capacity | 40VA |
Full load regulation rate | Less than 0.01% RG |
Full load regulation time | Less than 1mS |
Temperature drift | 8 PPM / °C |
Long-term stability | 60 PPM/year |
Power output | |
Active power accuracy | 0.05% or 0.1% |
Reactive power accuracy | 0.1% or 0.2% |
Stability | Better than 0.01% RG / 1 min |
Phase | |
Range | 0°-359.99° |
Adjustment resolution | 0.01°, 0.1°, 1°, 10° |
Accuracy | 0.03° |
Frequency | |
Range | 40-65 Hz |
Adjustment resolution | 0.001 Hz, 0.01 Hz, 0.1 Hz, 1Hz |
Accuracy | 0.002 Hz |
Temperature drift | 0.5 PPM / °C |
Long-term stability | 4 PPM/year |
Harmonic | |
Harmonic times | 2nd-63th |
Adjustment resolution | 0.1% (Compared with fundamental wave) |
Harmonic content (Compared with fundamental wave) | |
Voltage | ≤ 40% |
Current | ≤ 40% |
Phase | 0°-360° |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 420x320x155 |
Weight (kg) | 12 |
Environmental conditions | |
Operating temperature | 0°C to 40°C |
Storage conditions | -30°C to 60°C |
Relative humidity | ≤85% |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core ct and current clamp models etc.
GFUVE is a leader manufacturer of split core current transformer products in China. It is professional in current transformer, potential transformer and related accessory. The product of outdoor split core current transformer develops very quickly in the global market. Our company has achieved certification to ISO9001. The products are sold to over 30 provinces in China and exported to overseas including South America, Middle East, Southeast Asia, Australia and Africa.
Please contact us now for further business relationship. We are here to provide you the best service and the best product.