Gas Central Heating LCD Display For Room Heating And Sanitary Hot Water Home Gas Boiler
Technical data
Model Number | L1PB24 | L1PB32 |
Gas Type | NG/LPG | |
Rated Gas Pressure(Pa) | 2000/2800 | |
Rated Gas Input(kw) | 24 | 32 |
Rated Gas Output(kw) | 21.1 | 28.2 |
Efficiency Under Rated Heat Input(%) | Above88% | |
Power Supply | 20-50HZ | |
Electric Power(W) | 110 | 145 |
Temp.Range Of Heating Water(℃) | Radiator:30-80 Floor Heating:30-60 | |
Heating Area(㎡) | 100-200 | 200-300 |
Lift Of pump(m) | 5 | 7 |
Application Water Pressure(Mpa) | 0.1-0.3 | |
Expansion Tank Capacity(L) | 6 | 8 |
Preset Pressure Of Expansion Vessel(Mpa) | 0.1 | |
Water Circulation Type | Airtight Forced Circulation | |
△T=25℃ Hot Water Supply(kg/min) | 12 | 16 |
△T=30℃ Hot Water Supply(kg/min) | 10 | 13.3 |
Temp.Range Of DHW Supply(℃) | 30-60 | |
Applicative Water Pressure(mpa) | 0.03-0.8 | |
The Minimum Starting Flow (L/min) | 2 | |
The Minimum Closed Flow(L/min) | 1.6 | |
Connections(mm) | For Gas&Heating Water Pipes:G3/4 For DHW Pipes:G1/2 | |
Air Input/Exhaust Duct(mm) | φ60/φ100 | |
Sparated Input/Exhaust Duct(optional) | φ80/φ100 | |
The length Of Flue Dust(m) | 1 | |
Noise On Working(DB) | <42 | |
Exhaust Type | Forced Exhaust | |
Ignition Type | Integrated Automatic Ignition | |
Temperature Control | Gas Proportional Adjustment | |
Product Dimensions(mm) | 740*400*305 | 855*470*390 |
Packing Dimensions(mm) | 865*470*385 | 870*495*390 |
Container(20GP/40GP/40HQ) | 17//357/434 | 166/333/404 |
- With control circuit boards,control centers for high- intelligent equipment opeartion and safety protection.
- With multi-stage intelligent antifreeze,multi-stage combustion, the temperature is less than 8 degrees celsius
to start automatically, the pump after sycle in th burning to stop working, the pump.
- Delay opeartion to prevent overheating repeatedly.
- With LED- all round electronic display.
- The original modular design, assembly and disassembly is simple, fault memory function, convenient for the
rapid diagnosis of after sales personnel.
- The invention patent high-frequency electronic anti scalling device and the original windbreak and sand
structure design are committed to manufacturing gas wall hanging stove products suitable for our conditions.
- Dynamic fire display, automatic central control data output, intuitive and convenient.
- Touch buttons, big-screen dynamic LCD display, sensitive and comfortable.
- Digital precise temperature control system, are free to adjust temperature.
- Green environmental protection,ultra-low emission.
- Fan burner with full gas- air premix provides gas combustion with close to ideal conditions-so the condensation
process begin earlier and by higher return line temperature(about 57℃)
- Electronic controlled fan with variable rotation speed for keeping the optimal minimal required air exceed in the
gas-air mix.
- Modulation: boiler output changes automatically to keep the set heating and DHW temperature constant, with
great optimization of gas consumption.
- Indication of temperatures, working modes, current burner power and error codes on the color multifunctional
LCD display.
- PCB is insensitive to the electric polarity and fluctuations of voltage AC 160-242 Volt.
- Integrated 24-hour/week timer sets normal or lower heating temperature within each day of week with the benefits
of comfort and low gas consumption.
- Automatic electronic ignition and ionization flame control.
- Can connect with room thermostat and remote controller which can provide more function options.
- Working mode and error codes indication by 1 light- emitting diodes(LCD) on the control panel.
- Modulation: boiler output changes automatically to keep the set heating and DHW temperature constant, with great
optimization of gas consumption.
- Frost protection: burner and pump will be switch on automatically by danger of freezing, It is allowed to use antifreeze
liquid instead of water in the heating system.
- Supports outdoor temperature driven mode.
Foshan Shunde Dongyuan Gas Appliances Industrial Co., Ltd.
Foshan Shunde Dongyuan gas appliances Ind. Co.,Ltd as the professional wall hung gas boiler factory was established in 2007 and start to develop the overseas market from 2010. Dongyuan gas appliances Ind. Co.,Ltd have five fully automated wall-hung gas boiler production line with an annual capacity of 700,000 units,have two engineers with 23 years R&D experiences .With the powerful and skillful work team, rigid production and quality control ,DONGYUAN success to obtain the ISO9001, ISO14001 certificate, our boilers conform to the requests of CU-TR certificate and European standard, make they hot sale in Russia,Iran, Azerbaijan, Uzbekistan, Israel and other European and Middle East countries.
From mold design and material development to precision machining and products finishing, DONGYUAN exercises strict quality control on each production stage, not only produce traditional wall-mounted gas boiler, but also developed a condensing gas boiler with thermal efficiency up to 105%.