Intelligent Universal 690V Moulded Case Circuit Breaker
Introduction
HKW2-1600 intelligent universal circuit breaker (hereinafter
referred to as circuit breaker), suitable for AC 50Hz, rated
working voltage
To 690V, rated current 200 ~ 1600A distribution network, used to
distribute electrical energy and protect the circuit and power
equipment from overload,
The hazards of short circuit, under voltage, single-phase grounding
(leakage) and other faults. The circuit breaker has intelligent
protection function, selective protection is accurate,
Can improve power supply reliability and avoid unnecessary power
outages. At the same time with an open communication interface,
easy to connect with the field bus, can
Realize the "four remote" functions to meet the requirements of
control centers and automation systems. Configure corresponding
leakage transformer and intelligent controller
You can achieve leakage protection.
The circuit breaker has an isolation function and is represented by
the symbol "_".
Circuit breakers with a rated operating current of 630A and can
also be used as electric power in AC 50(60)Hz, 400V distribution
networks
The machine is protected against overload, short circuit, phase
loss, under voltage and ground faults. Under normal conditions, the
circuit breaker can also be used as a line
Infrequent conversion and infrequent start of the motor.
The circuit breaker complies with GB 14048.2- -2012 "Low-voltage
switchgear and control equipment Part 1: General rules"; and GB
14048.2
-2008 "Low-voltage switchgear and control equipment Part 2: Circuit
breakers"; GB14048.2- 2010 "Low-voltage switchgear
And control equipment Part 4-1: contactors and motor starters
electromechanical contactors and motor starters" and other
standards.
Name: | Circuit Breaker | Rated Voltage: | 690V |
---|---|---|---|
Rated Current: | 200 ~ 1600A | Short Circuit Splitting Capacity: | 20kA~42kA |
Poles: | 3/4 Poles | Feature: | Full Intelligence, High Segmentation |
Feature
O has the characteristics of full intelligence, high segmentation,
zero arc flash, etc.;
O AC rated current 200A-1600A, short circuit breaking capacity
20kA~42kA;
O has 3 poles and 4 poles, drawer type and fixed type, can be
installed into the line;
O has a variety of intelligent controllers, providing different
functions: intelligent function, display function.
0 setting function, monitoring function, fault memory function, can
bring communication interface to achieve telemetry, remote
adjustment, remote control, remote communication;
O protection features are complete, easy to set, high precision,
with instantaneous, short delay, long delay, single-phase grounding
and other protection features.
classification
◎According to the use category:
Main circuit: Class A (non-selective type), Class B (selective
type) and AC-3 (direct operation motor);
Auxiliary circuit: AC-15, DC-13;
◎ Installation method: fixed type, drawer type;
◎ Transmission mode: motor drive, manual;
◎Number of poles: three poles, four levels;
◎Release type: intelligent controller, shunt release, undervoltage
instant (or delay) release;
◎Classification of intelligent controller:
2M type: economic type (basic function)
3M type: basic type (basic function + intelligent function)
3H type: Advanced type (basic function + intelligent function +
communication interface).
Normal working conditions and installation conditions
◎Ambient air temperature: the upper limit does not exceed +409C;
the lower limit does not exceed -5C; the average value of 24h does
not exceed +35C;
Note: For working conditions where the ambient air upper limit
value exceeds +40C or the lower limit value is less than -25°C, the
user should consult with the manufacturer.
◎ Altitude: The altitude of the installation site does not exceed
2000m.
◎Atmospheric conditions: when the maximum temperature is +40C, the
relative humidity of the air does not exceed 50%, and it can have a
higher temperature at a lower temperature
Relative humidity, such as 90% at 20°C, special measures should be
taken for occasional exposure due to temperature changes.
◎Pollution level: Level 3
◎The circuit breaker is installed in the cabinet, and the door
frame is installed, and the protection level reaches IP40.
◎The main circuit of the circuit breaker and the coil of the
undervoltage release, the installation category of the primary coil
of the power transformer is IV, and the remaining auxiliary
circuits,
The control circuit installation category is II.
◎Category of use: Class B.
◎Transportation and storage conditions of circuit breaker: -25C to
55C, up to +70C in a short time (within 24h).
◎Short circuit should be installed in a place without explosion
risk and conductive dust, no enough to corrode metal and destroy
insulation, and the circuit breaker
The vertical inclination does not exceed 5°C.
WENZHOU QIUPU ELECTRIC POWER CO., LTD.
Wenzhou Qiupu Electric Power Co., Ltd. is located in Yueqing
Economic Development Zone, Zhejiang Province. It is a high-tech
enterprise specializing in the research and development, production
and sales of electric power products such as circuit breakers,
transformers, power distribution switches and high and low voltage
electrics. Our products are widely used in financial,
communications, municipal, transportation, power, construction,
aerospace, industrial control and other important areas, has won
the majority of users praise and signed a long-term cooperation
agreement.
As an innovative technology-based
enterprises, the company has strong technical force and the world's
leading production technology and high-end testing equipment, and
establish and improve the procurement of components, product
processing assembly, testing, packaging to sell a complete set
Quality management system to ensure that every product of the
eligibility, the company has 10 years of experience in the power
industry, and is still growing, product and sales network
throughout the country.