Home /

PLA403 Plasma Probe Used for Laryngeal Tumor Resection and Papilloma Resection

Send your message to this supplier
*From:
Your email address is incorrect!
To:Chengdu Mechan Electronic Technology Co., Ltd
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap PLA403 Plasma Probe Used for Laryngeal Tumor Resection and Papilloma Resection from wholesalers
  • Buy cheap PLA403 Plasma Probe Used for Laryngeal Tumor Resection and Papilloma Resection from wholesalers

PLA403 Plasma Probe Used for Laryngeal Tumor Resection and Papilloma Resection

Ask Latest Price
Model Number:PLA403
Certification:CE, ISO
Price:Negotiable
Payment Terms:T/T, L/C, Western Union
Brand Name:Mechan
Company Data
Verified Supplier
Contact Person Townie
Business Type: Manufacturer Exporter
Officials: No. 11, District 9, Huayin Industrial Harbor, No. 618, West Kelin Road, Chengdu Straits Science & Tech Industrial Development Park, Wenjiang District, Chengdu city, Sichuan Province, China. 611130
Quality: Quality Certifitation Available
Visit Website
Product Details Company Profile
Product Details

PLA403 Plasma Probe Used for Laryngeal Tumor Resection and Papilloma Resection


Operation Guidance

  • When the cable plug of disposable plasma probe is correctly connected to the equipment, the equipment will display the default power value. Each plasma probe has the maximum power limitation.
  • The disposable plasma probe connection wire shall be correctly placed, so as to prevent it from being damaged, thus contacting the patient or other charged conductors.
  • During the operation, the medium (such as saline, Lactic Acid Ringer's Solution, etc.) should be dripped to the tip of the electrode. Raising the height of the saline bag due to the gravity would support the medium drip onto the tip of the electrode with the application of saline flow controller.

A. Connect the suction tube of the disposable plasma probe to the standard surgical aspirator.

Caution: When the plasma probe is not used, turn off the saline drip to prevent scalded patients

Caution: Suction pipe could not be in contact with patients, it might scald patients if suction objects were hot.

B. Adjust the flow regulating knob on the drip pipe and set the appropriate flow rate for the plasma probe.

Precaution: The flow regulating knob should be opened wider to ensure that there is continual flow of saline.

Caution: Remove the plasma probe from the patient when fixing the plasma probe drip pipe or setting the flow rate of saline, otherwise the fluid may scald the patient.

C. Caution: In the process of ablation and coagulation, the operating surgeon shall be aware that the electronic equipment can cause electrical stimulation to muscle tissues.

Caution: When saline flows through the electrode, the temperature may rise, so it should be avoided that saline flows to the non-surgical area. When the plasma probe is installed or cleaned, please ensure that there is a container to collect waste saline.


Tips

1. During the surgery, the tissue should be ablated from bottom to top, from the middle to the side little by little. To the electrode with absorption function: in order to achieve the best electrode performance, it must have enough suction. A certain gap between the electrode and the tissue should be useful for avoid blocking. Once the aspirator does not working, the operation should be stopped and the plasma probe, suction tube and aspirator should be checked. If the absorption function does not work properly, it indicates that the plasma probe is blocked, or the aspirator does not work properly.

  • Do not insert the tip of the probe into the tissue, but keep moving the tip. In the process of ablation, the absorption hole will absorb the residue to keep the surgical incision cleaning.

3. Small area bleeding can basically be stopped in the ablation process. However, if the coagulation function is needed, please put the electrode surface to the bleeding position and set the coagulation function at the same time. Loosen the blood vessels, and then check the bleeding point again.

4. During the surgery, please prepare wet cotton soaked with saline, and wipe the dirt on the tip of the electrode at any time. Before ablate the other side of the tonsil, please make sure that the tip has been wiped and cleaned.

5. Once the disposable plasma probe is blocked, it should be taken out of the incision and immersed in the cup with saline, and then activate the probe with the maximum output power at the same time. If it is still blocked, you can use the syringe to inject saline into the suction pipe by the opposite direction towards the tip of the probe, and output the maximum power at the same time.


PLA403 Plasma Probe Used for Laryngeal Tumor Resection and Papilloma Resection

Company Profile

Chengdu Mechan Electronic Technology Co., Ltd

Chengdu Mechan Electronic Technology Co., Ltd.

 

Established in 2002, Mechan Medical is a high-tech medical enterprise with the integration of R&D, manufacture and marketing. It is the pioneer of research, development and manufacturing plasma medical products in mainland China. Mechan Medical is devoted to low-temperature plasma surgery system for minimally-invasive, and our products at present cover ENT, Orthopedics, Urology, Gynecology, Ophthalmology, Anorectal, etc.

 

The company has listed on the new third board on August 18, 2015, wherein the stock code is 833234 and the stock abbreviation is: Mechan Medical.

 

 

We has a strong record of medical sales and service network, including 31 provinces and cities nationwide, and our products are exported to over 10 countries,including Isreal, South Korea, Saudi Arabia, Iran, Brasizl, the United Arab Emirates, Indonesia etc. We have mastered the core technology of low temperature plasma through the cooperation of Томский политехнический университет and Shenyang Ligong University, and established the company Mechan Europe in UK.

 

In order to make the products go better out of the country and understand the international most advanced plasma minimally invasive medical technology, we and which means our quality is accepted by the European market.

 

In October 2014, obtained the qualification as a hi-tech enterprise

In November 2014, CE marked

In January 2015, got invention patent of Low temperature plasma technology

In May 2015, started to apply for the international patents in America and EU

 

Our vision is to become a professional company taking low temperature plasma technology as core to produce minimally invasive products for whole departments, and make the low-temperature plasma technology as the must tool for surgeons .

At the same time of perfecting ENT Products, we constantly develop our products for Orthopedics, Gynecology, Urology, Ophthalmology, Digestion, Anorectal, Plastic surgery, General surgery, and so on.

Our goal is to make Chengdu Mechan the leading pioneer of the low-temperature plasma products in China, and make the Company a famous and respected medical enterprise.

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Chengdu Mechan Electronic Technology Co., Ltd

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China Tonsillectomy Plasma Wand ENT Probe For Minimally Invasive Plasma Surgery wholesale

Tonsillectomy Plasma Wand ENT Probe For Minimally Invasive Plasma Surgery

China Plasma Ablation Turbinate Reduction ENT Probe Minimally Invasive Surgical wholesale

Plasma Ablation Turbinate Reduction ENT Probe Minimally Invasive Surgical

China Plasma ENT Surgery Instruments , Coblator Turbinate Wand For Pediatric Turbinate Channeling wholesale

Plasma ENT Surgery Instruments , Coblator Turbinate Wand For Pediatric Turbinate Channeling

China Durable ENT Probe For Turbinate Channeling Minimally Invasive Plasma Surgery wholesale

Durable ENT Probe For Turbinate Channeling Minimally Invasive Plasma Surgery

China Soft Palate Uvula Wand Ent Surgical Instruments Ablation Adjustable From 1 To 10 wholesale

Soft Palate Uvula Wand Ent Surgical Instruments Ablation Adjustable From 1 To 10

China PLA401 Ent Surgery Instruments ENT Probe For Snoring Treatment System wholesale

PLA401 Ent Surgery Instruments ENT Probe For Snoring Treatment System

China Minimally Invasive Ent Medical Instruments For Snoring Treatment Coblator Adenoidectomy wholesale

Minimally Invasive Ent Medical Instruments For Snoring Treatment Coblator Adenoidectomy

China Minimally Invasive ENT Probe For Snoring Treatment Coblation Adenoidectomy wholesale

Minimally Invasive ENT Probe For Snoring Treatment Coblation Adenoidectomy

China Low Temperature Precise Surgical Ent Instruments Tonsillectomy Plasma Wand wholesale

Low Temperature Precise Surgical Ent Instruments Tonsillectomy Plasma Wand

China Mechan Plasma ENT Probe for Tubinate Channeling and Ablation wholesale

Mechan Plasma ENT Probe for Tubinate Channeling and Ablation

China Plasma Surgical Device turbinate wand ablation electrode for Snoring procedure,Soft Palate Reduction,Uvulopalatoplasty wholesale

Plasma Surgical Device turbinate wand ablation electrode for Snoring procedure,Soft Palate Reduction,Uvulopalatoplasty

Inquiry Cart 0