Home /

7Inch LCD CT PT Current Transformer Analyzer 0.02% Accuracy Support USB Flash

Send your message to this supplier
*From:
Your email address is incorrect!
To:Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap 7Inch LCD CT PT Current Transformer Analyzer 0.02% Accuracy Support USB Flash Disk from wholesalers
  • Buy cheap 7Inch LCD CT PT Current Transformer Analyzer 0.02% Accuracy Support USB Flash Disk from wholesalers
  • Buy cheap 7Inch LCD CT PT Current Transformer Analyzer 0.02% Accuracy Support USB Flash Disk from wholesalers

7Inch LCD CT PT Current Transformer Analyzer 0.02% Accuracy Support USB Flash Disk

Ask Latest Price
Brand Name:GFUVE
Model Number:GF1061-2
Certification:CE, ISO9001
Price:Negotiable
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability:200SETS/MONTH
Delivery Time:2-3weeks
Company Data
Verified Supplier
Contact Person Andy
Business Type: 86-10-85782698
Business Type: Manufacturer
Officials: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Quality: Quality Certifitation Available
Product Details Company Profile
Product Details

0.02% Accuracy 4KG 7Inch LCD CT PT Analyzer for testing CT and PT


GF1061 0.02% Accuracy 4KG 7Inch LCD CT PT Analyzer for testing CT and PT portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.


Features


1. Very Steady and transient state characteristic tests of 90% types of CT/PT

2. The use of advanced power technology, the test knee point reaches up to 30kV,can be customzied to 40KV also.

3. No external other auxiliary equipment, stand-alone to complete all test items

4. CT test, easy to test, all the tests are using the same wire connection except the load test

5. It carries with thermal printer, so it can print test results on site Reference Standard IEC 60044-1-2, ANSI/ IEEE C57.13, IEC61869, GB 1207-2006, GB 1208-2006

6. Parameters such as knee point current and voltage

7. Parameters such as 10% error curve, 5% error curve

8. With battery, working 48hours full load working/

9. The device can store 10000 groups of test data which would not be lost if the device is power off.

10. The data can be displayed and analyzed after the test, or transferred to PC through USB disk and produce a Word file report

11. Portability: weight <4kg, the best light ct analyzer


MAIN FUNCTIONS

I. Current Transformer (CT)II. Voltage Transformer (PT)
1. Magnetization curve1. Excitation characteristic test
2. Transformation ratio test2. Transformation ratio test
3. Polarity3. Polarity
4. 5% and 10% error curve4. Ratio error, phase error
5. Accuracy limiting factor (ALF)5. Degauss
6. Degauss6. Calculation of knee point value
7. Ratio error, phase error7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test (burden test)
10. Resistance test 
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error

PARAMETERS


Electrical parameters
Accuracy0.05%
Power supplyAC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage0-100Vrms
Output current0-5Arms (20A peak-value)
Output power0-400 VA (1500 VApeak)
Automatic frequency variation range0.1-60Hz
Equivalent excitation voltage≤5000V
Accuracy≤0.5%
Secondary winding DC resistance measurementRange0.1-1000Ω
Accuracy≤0.05%
Secondary actual load measurementRange5VA-1000VA
Accuracy≤0.5%±0.1VA
CT/PT phase error measurementAccuracy±1min (typical) / 3 min (guaranteed)
Resolution0.1min
CT ratio error measurementRange1-50000
Accuracy≤0.05%
PT ratio error measurementRange1-10000
Accuracy≤0.05%
Standards 
Reference standardsGB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standardsGB 4793.1-2007
EMCEMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters 
Overall dimension (L x W x H) (mm)280 x 250 x 160
Weight (kg)≤4
Environmental conditions 
Relative humidityRelative humidity 5%-95% not condensing
Operating temperature-10°C to +50°C
Storage temperature-20°C to +70°C
Altitude≤1000m

Photo

7Inch LCD CT PT Current Transformer Analyzer 0.02% Accuracy Support USB Flash Disk

Company Profile

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core ct and current clamp models etc.

GFUVE is a leader manufacturer of split core current transformer products in China. It is professional in current transformer, potential transformer and related accessory. The product of outdoor split core current transformer develops very quickly in the global market. Our company has achieved certification to ISO9001. The products are sold to over 30 provinces in China and exported to overseas including South America, Middle East, Southeast Asia, Australia and Africa.

Please contact us now for further business relationship. We are here to provide you the best service and the best product.

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China 1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing wholesale

1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing

China GF106 CT PT Analyzer Ct Pt Testing Equipment Type Printer Portable Accuracy 0.05% wholesale

GF106 CT PT Analyzer Ct Pt Testing Equipment Type Printer Portable Accuracy 0.05%

China Automatic Smart IEC60044-1 Pt Potential Transformer wholesale

Automatic Smart IEC60044-1 Pt Potential Transformer

China 4.8KG Weight CT PT Analyzer Voltage Transformer Analyzer 0.02% / 0.05% Accuracy wholesale

4.8KG Weight CT PT Analyzer Voltage Transformer Analyzer 0.02% / 0.05% Accuracy

China Portable GFUVE CT PT Analyzer Current Transformer Testing IEC60044-1 wholesale

Portable GFUVE CT PT Analyzer Current Transformer Testing IEC60044-1

China GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification wholesale

GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification

China Electronic Power Power Quality Analyzer Portable Ct Testing Equipment 4kg Weight wholesale

Electronic Power Power Quality Analyzer Portable Ct Testing Equipment 4kg Weight

China Electronic Ct Test Equipment High Precision GF1061 Easy Operation For Lab Testing wholesale

Electronic Ct Test Equipment High Precision GF1061 Easy Operation For Lab Testing

China Portable Potential Current Transformer Testing Equipments With Ct Test Function wholesale

Portable Potential Current Transformer Testing Equipments With Ct Test Function

China Portable Voltage PT Power Transformer Testing Equipment With Polarity 4.8KG wholesale

Portable Voltage PT Power Transformer Testing Equipment With Polarity 4.8KG

China Automatic Transformer Test Instruments 0.05% Accuracy Ct Testing Equipment wholesale

Automatic Transformer Test Instruments 0.05% Accuracy Ct Testing Equipment

Inquiry Cart 0