Standard Closed Loop Cooling Tower 1635kw Heat Reject For Industrial Architecture
Description
1.closed cooling towers are Using the counter flow cooling way; few
cooling blind area, high thermal efficiency:
2. Efficiency of cooling tower is to adopt the professional and
efficient water collector to control the running floating rate
,that is less or equal to 0.001%;
3.Closed cooling tower in high air duct design to make sure the
equipment to meet the demand of cooling air flow rate during
operation;
4. Reduce the occupied area compare to other types of cooling tower
to meet the users' space demanding;
5.The tank of cooling tower adopts closed loop, eliminate clutters
go into the tower body to produce spraying blocked;
6.The important part of counterflow cooling tower is the cooler
that uses the antifreeze energy-saving design, to ensure the
circulating water drain up and avoid freezing in the northern
region with low temperature;
7.Design two-circuit cycle according to the demands of custom's
devices, even if one circulation failure, anther cycle can be still
normally operating;
8.The cooling tower design of units are elegant appearance,
automatic digital display, easy to maintain.
Item
FBN-300T Specifications | |
Heat Reject | 1635kw |
Nominal Flow Rate | 300 m3/h |
Work Flow Rate | 235 m3/h |
Fan Power | 2×11kw |
Wind Flow Rate | 2×120000m3/h |
Spray Pump Power | 7.5kw |
Spray Water Flow Rate | 172m3/h |
Spray Pump Raise | 9.6m |
Inlet/Outlet Diameter | DN 200mm |
Makeup Connection | DN40 (Please specify adopted screw standards) |
Bleed Line Diameter | DN50 (Please specify adopted screw standards) |
Net Weight | 5150kg |
Operate Weight | 9500kg |
Dimensions | 5100×2300×4950mm |
The biggest difference between closed cooling tower and open cooling tower: The closed cooling tower will be cooled by the cooling medium through the coil and the cooling water and air outside the tube,formed a closed loop system, to avoid the cooling medium due to contact with air and lead to pollution, resulting in a waste of the cooling medium, equipment congestion and other failures affect the normal use. This equipment is suitable for use in harsh environments such as drought, water shortage and dust storms. It can be used in central air conditioning, instrumentation, metallurgical intermediate frequency electric furnace, converter, power plant generating units, steam turbine nuclear power plant, substation, chemical, pharmaceutical, welding, rolling aluminum, copper foil cooling oil, large hydraulic machinery hydraulic Oil and other industrial manufacturing use.
SHANGHAI YANYE INDUSTRIAL EQUIPMENT CO.,LTD
Shanghai Yanye industrial Cooling Equipment Co., Ltd ( YANYE Cooling ) is a manufacturing plant for provision of various industrial & commercial cooling solutions. The system ranges from the cooling of water to gas, oil and miscellaneous industrial fluid mediums, with a strong emphasis on the manufacturing of closed circuit cooling towers and evaporative condensers.
Located in both Shanghai and Wuxi cities, YANYE Cooling owns one of the largest production scope of modern closed circuit cooling tower and evaporative condenser manufacture in China, covering an area of approx. 30.000 square meters, with an assembly workshop of 18,000 square meters.
With superb quality and exquisite manufacture technique, Yanye Cooling has won wide recognition from customers in the fields of heat treatment, metal & plastic melting, forging, air conditioning, compressor, power plant and chemical industries etc. With great reputation, WELL is honorable to have supplied her cooling systems to AGC(Japan), Saint-Gobain (France), Vaillant (Germany), Sanmina-SCI (USA), Danaher (USA), Stanly (USA), Aichelin (Austria), Mecaplast (France) and China Telecom etc global leading images.
With constant enthusiasm, YANYE COOLING team is working toward
the goal of becoming one leading enterprise in the international
lines.